LC1D09P7 Schneider Contc Electric

Technical Specification 

  • Range: TeSys
  • Product name: TeSys D
  • Product or component type: Contactor
  • Device short name: LC1D
  • Contactor application:
    • Motor control
    • Resistive: load
  • Utilisation category:
    • AC-4
    • AC-3
    • AC-1
  • Poles description: 3P
  • Power pole contact composition: 3 NO
  • [Ue] rated operational voltage:
    • <= 300 V DC for power circuit
    • <= 690 V AC 25...400 Hz for power circuit
  • [Ie] rated operational current:
    • 25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
    • 9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
  • Motor power KW:
    • 2.2 kW at 400 V AC 50/60 Hz AC-4
    • 2.2 kW at 220...230 V AC 50/60 Hz AC-3
    • 4 kW at 380...400 V AC 50/60 Hz AC-3
    • 5.5 kW at 500 V AC 50/60 Hz AC-3
    • 5.5 kW at 660...690 V AC 50/60 Hz AC-3
    • 4 kW at 415...440 V AC 50/60 Hz AC-3
  • Control circuit type: AC 50/60 Hz
  • [Uc] control circuit voltage: 230 V AC 50/60 Hz
  • Auxiliary contact composition: 1 NO + 1 NC
  • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
  • [Ith] conventional free air thermal current:
    • 25 A at <= 60 °C for power circuit
    • 10 A at <= 60 °C for signalling circuit
  • [Icw] rated short-time withstand current 105 A <= 40 °C 10 s power circuit:
    • 210 A <= 40 °C 1 s power circuit
    • 30 A <= 40 °C 10 min power circuit
    • 61 A <= 40 °C 1 min power circuit
    • 100 A 1 s signalling circuit
    • 120 A 500 ms signalling circuit
    • 140 A 100 ms signalling circuit
  • Electrical durability:
    • 0.6 Mcycles 25 A AC-1 at Ue <= 440 V
    • 2 Mcycles 9 A AC-3 at Ue <= 440 V
  • Standards CSA:
    • C22.2 No 14
    • EN 60947-4-1
    • EN 60947-5-1
    • IEC 60947-4-1
    • IEC 60947-5-1
    • UL 508

Complementary:

  • Coil technology Without built-in suppressor module
  • Control circuit voltage limits
    • 0.3...0.6 Uc drop-out at 60 °C, AC 50/60 Hz
    • 0.8...1.1 Uc operational at 60 °C, AC 50 Hz
    • 0.85...1.1 Uc operational at 60 °C, AC 60 Hz
  • Inrush power in VA
    • 70 VA at 20 °C (cos ϕ 0.75) 60 Hz
    • 70 VA at 20 °C (cos ϕ 0.75) 50 Hz
  • Hold-in power consumption in VA
    • 7.5 VA at 20 °C (cos ϕ 0.3) 60 Hz
    • 7 VA at 20 °C (cos ϕ 0.3) 50 Hz
  • Heat dissipation: 2...3 W at 50/60 Hz
  • Auxiliary contacts type
    • Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
    • Type mirror contact (1 NC) conforming to IEC 60947-4-1
  • Signalling circuit frequency: 25...400 Hz
    • minimum switching current: 5 mA for signalling circuit
    • minimum switching voltage: 17 V for signalling circuit
  • Non-overlap time
    • 1.5 ms on energisation between NC and NO contact
    • 1.5 ms on de-energisation between NC and NO contact
  • Insulation resistance: > 10 MOhm for signalling circuit