Schneider Electric Contactor 18A 230V 50/60HZ - LC1D18P7

Schneider ElectricSKU: LC1D18P7

Price:
£39.45

Description

LC1D18P7 Schneider Contc Electric

  • Control circuit voltage: 230V AC 50/60Hz
  • Product certifications: BV, CCC, CSA, DNV, GL, GOST, RINA, UL
  • Utilisation category: AC-1 & AC-3
  • Operating time: 4 to 19ms opening
  • Operating time: 12 to 22ms closing
  • Mechanical durability: 15mcycles
  • Connections: screw clamp terminals

Product Description

From the TeSys LC1D series, a 3-pole (3 NO) category AC-1 / AC-3 contactor rated at 18A (AC-3) / 32A (AC-1) with a 230V AC coil.

Technical Specification 

  • Range: TeSys
  • Product or component type: Contactor
  • Device short name: LC1D
  • Contactor application:
    • Resistive load
    • Motor control
  • Utilisation category:
    • AC-4
    • AC-3
    • AC-1
    • Poles Description: 3P
    • Power pole contact composition: 3 NO
    • [Ue] rated operational voltage:
      • <= 300 V DC for power circuit
      • <= 690 V AC 25...400 Hz for power circuit
    • [Ie] rated operational current:
      • 18 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
      • 32 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
    • Motor power KW:
      • 10 kW at 500 V AC 50/60 Hz AC-3
      • 10 kW at 660...690 V AC 50/60 Hz AC-3
      • 4 kW at 220...230 V AC 50/60 Hz AC-3
      • 7.5 kW at 380...400 V AC 50/60 Hz AC-3
      • 9 kW at 415...440 V AC 50/60 Hz AC-3
      • 4 kW at 400 V AC 50/60 Hz AC-4
    • Control circuit type: AC 50/60 Hz
    • [Uc] control circuit voltage: 230 V AC 50/60 Hz
    • Auxiliary contact composition: 1 NO + 1 NC
    • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
    • [Ith] conventional free air thermal current:
      • 32 A at <= 60 °C for power circuit
      • 10 A at <= 60 °C for signalling circuit
    • Standards:
      • CSA C22.2 No 14
      • EN 60947-4-1
      • EN 60947-5-1
      • IEC 60947-4-1
      • IEC 60947-5-1
      • UL 508
    • Product certifications
      • BV
      • CCC
      • GL
      • CSA

    Complementary:

    • Coil technology: Without built-in suppressor module
    • Control circuit voltage limits
      • 0.3...0.6 Uc drop-out at 60 °C, AC 50/60 Hz
      • 0.8...1.1 Uc operational at 60 °C, AC 50 Hz
      • 0.85...1.1 Uc operational at 60 °C, AC 60 Hz
    • Inrush power in VA
      • 70 VA at 20 °C (cos ϕ 0.75) 60 Hz
      • 70 VA at 20 °C (cos ϕ 0.75) 50 Hz
    • Hold-in power consumption in VA
      • 7.5 VA at 20 °C (cos ϕ 0.3) 60 Hz
      • 7 VA at 20 °C (cos ϕ 0.3) 50 Hz
    • Heat dissipation: 2...3 W at 50/60 Hz
    • Auxiliary contacts type
      • Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
      • Type mirror contact (1 NC) conforming to IEC 60947-4-1
    • Signalling circuit frequency: 25...400 Hz
    • minimum switching current: 5 mA for signalling circuit
    • minimum switching voltage: 17 V for signalling circuit
      • Non-overlap time
        • 1.5 ms on energisation between NC and NO contact
        • 1.5 ms on de-energisation between NC and NO contact
      • Insulation resistance: > 10 MOhm for signalling circuit

      Downloads

      LC1D18P7 Instructions

       

       

      LC1D18P7 Datasheet

        Payment & Security

        Amazon American Express Apple Pay Google Pay Maestro Mastercard PayPal Shop Pay Visa

        Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

        You may also like